• SFP28 25Gb/s Direct Attached Cable

SFP28 25Gb/s Direct Attached Cable

The SFP28 passive cable assemblies are high performance, cost effective I/O solutions for 25G Ethernet. SFP28 copper cables allow hardware manufactures to achieve high port density, configurability and utilization at a very low cost and reduced power budget.

Product description

PRODUCT FEATURES

•Up to 25.78125 Gbps data rate
•Up to 7meter transmission
•Hot-pluggable SFP 20PIN footprint
•Compliant with SFF-8402 and SFF-8432
•Temperature Range: 0~ 70 °C
•RoHS Compliant

APPLICATIONS

•25G Ethernet

PRODUCT DESCRIPTION

The SFP28 passive cable assemblies are high performance, cost effective I/O solutions for 25G Ethernet. SFP28 copper cables allow hardware manufactures to achieve high port density, configurability and utilization at a very low cost and reduced power budget.

Ordering Information

Part Number

Description

SP28-DP1M30WG

25G SFP28 DAC Passive cable 30AWG 1M

SP28-DP2M30WG

25G SFP28 DAC Passive cable 30AWG 2M

SP28-DP3M30WG

25G SFP28 DAC Passive cable 30AWG 3M

SP28-DP3M30WG

25G SFP28 DAC Passive cable 26AWG 3M

SP28-DP5M26WG

25G SFP28 DAC Passive cable 26AWG 5M

SP28-AP7M26WG

25G SFP28 DAC Active cable 26AWG 7M 

High Speed Characteristics

Parameter

Symbol

Min

Typical

Max

Unit

Note

Differential Impedance

TDR

90

100

110

ohms

 

Insertion loss

SDD21

8

 

22.48

dB

At 12.8906 GHz

Differential Return Loss

SDD11

SDD22

12.45

  See 1

dB

At 0.05 to 4.1 GHz

3.12

 

See 2

dB

At 4.1 to 19 GHz

Common-mode to common-mode output return loss

SCC11

SCC22

2

   

dB

At 0.2 to 19 GHz

Differential to common-mode

return loss

SCD11

SCD22

12

 

See 3

dB

At 0.01 to 12.89 GHz

10.58

 

See 4

At 12.89 to 19 GHz

Differential to common Mode

Conversion Loss

SCD21-IL

10

 

 

dB

At 0.01 to 12.89 GHz

    See 5

At 12.89 to 15.7 GHz

6.3

 

 

At 15.7 to 19 GHz

Channel Operating Margin

COM

3

   

dB

 
Notes:

  1. Reflection Coefficient given by equation SDD11(dB) < 16.5 - 2 × SQRT(f ), with f in GHz
  2. Reflection Coefficient given by equation SDD11(dB) < 10.66 - 14 × log10(f/5.5), with f in GHz
  3. Reflection Coefficient given by equation SCD11(dB) < 22 - (20/25.78)*f, with f in GHz
  4. Reflection Coefficient given by equation SCD11(dB) < 15 - (6/25.78)*f, with f in GHz
  5. Reflection Coefficient given by equation SCD21(dB) < 27 - (29/22)*f, with f in GHz

 

SFP28 Pin Function Definition

a

Pin

Logic

Symbol

Name/Description

Notes

1

 

VeeT

Transmitter Ground

 

2

LV-TTL-O

TX_Fault

N/A

1

3

LV-TTL-I

TX_DIS

Transmitter Disable

2

4

LV-TTL-I/O

SDA

Tow Wire Serial Data

 

5

LV-TTL-I

SCL

Tow Wire Serial Clock

 

6

 

MOD_DEF0

Module present, connect to VeeT

 

7

LV-TTL-I

RS0

N/A

1

8

LV-TTL-O

LOS

LOS of Signal

2

9

LV-TTL-I

RS1

N/A

1

10

 

VeeR

Reciever Ground

 

11

 

VeeR

Reciever Ground

 

12

CML-O

RD-

Reciever Data Inverted

 

13

CML-O

RD+

Reciever Data Non-Inverted

 

14

 

VeeR

Reciever Ground

 

15

 

VccR

Reciever Supply 3.3V

 

16

 

VccT

Transmitter Supply 3.3V

 

17

 

VeeT

Transmitter Ground

 

18

CML-I

TD+

Transmitter Data Non-Inverted

 

19

CML_I

TD-

Transmitter Data Inverted

 

20

 

VeeT

Transmitter Ground

 

1.

Signals not supported in SFP+ Copper pulled-down to VeeT with 30K ohms resistor  

2.

Passive cable assemblies do not support LOS and TX_DIS  

 

Mechanical Specifications

The connector is compatible with the SFF-8432 specification.

a

 

Regulatory Compliance

Feature Test Method Performance
Electrostatic Discharge (ESD) to the Electrical Pins  MIL-STD-883C Method 3015.7  Class 1(>2000 Volts)
Electromagnetic Interference (EMI) FCC Class B Compliant with Standards
CENELEC EN55022 Class B
CISPR22 ITE Class B
 RF Immunity (RFI)  IEC61000-4-3 Typically Show no Measurable Effect from a 10V/m Field Swept from 80 to 1000MHz
RoHS Compliance RoHS Directive 2011/65/EU and it's Amendment Directives 6/6 RoHS 6/6 compliant

 


  • Previous:
  • Next:

  • Write your message here and send it to us

    Related Products

    More +
    • QSFP+ 40Gb/s to 4SFP+ Direct Attached Cable

      QSFP+ 40Gb/s to 4SFP+ Direct Attached Cable

    • MPO MTP Optical Fiber Patchcord

      MPO MTP Optical Fiber Patchcord

    • Fiber Array

      Fiber Array

    • MTPMPO-LC fibers om3-cables

      MTPMPO-LC fibers om3-cables